The Compressed Air Purity and Quality You Require
NOAVAR Gives You the Compressed Air Purity and Quality You Require
A typical compressed air system is contaminated with abrasive solid particles such as dust , dirt , rust and pipe scale , compressor lubricants ( mineral or synthetic ) , condensed water droplets and acidic condensates and oil and hydrocarbon vapors . if not removed , these contaminants increase pneumatic equipment maintenance costs , lead to instrument and control failure , contribute to poor product fit and finish and contaminate processes . The right filter or filter system will remove these contaminants allowing your compressed air system to deliver the quality of air required by your application … whether its plant air , instrument air , or medical air … helping to ensure consistent output quality while minimizing operating costs.
Filters feature:
- Push-on elements make element replacement easy
- Piston type element to housing seal keeps unfiltered air from by-passing element
- Corrosion resistant cores-stainless steel for added structural integrity
- Low resistance to flow-seam welded for extra strength
- New " matrix blended fiber " media – large , effective surface area – improves capture rate
- Ensure high efficiencies-large open area minimizes pressure drop
- Coated , closed cell foam sleeve – resists chemical attack from oils and acids
- Ensures high efficiencies by preventing re-entrainment of coalesced liquids
- Chemically resistant end caps bound to media with specially formulated adhesive
- Silicone free
- Withstands temperatures to 150 F ( 66 C )
- Low resistance to flow
A typical compressed air system is contaminated with abrasive solid particles such as dust , dirt , rust and scale , compressor lubricants ( mineral or synthetic) , condensed water droplets and acidic condensates and oil and hydrocarbon vapors . If not removed , these contaminants increase pneumatic equipment maintenance costs , lead to instrument and control failure , contribute to poor product fit and finish and contaminate processes . The right filter or filter system will remove these contaminants allowing your compressed air system to deliver the quality of air required by your application … whether its plant air , instrument air , or medical air … helping to ensure consistent output quality while minimizing operating costs
|
REPLACEMENT ELEMENT KIT |
WEIGHT
(kg) |
DIMENSIONS (mm) |
FLOW RATES
@7 bar g (100 psi g) |
PIPE SIZE |
FILTER TYPE |
|
NO |
Type |
E |
D |
C |
B |
A |
M3/hr |
cfm |
L/S |
|
1 |
K003 (grade) |
0.1 |
45 |
_ |
89 |
9.75 |
58 |
11 |
6 |
3 |
8mm Push Fit |
(grade) 0003G |
|
1 |
K009 (grade) |
0.5 |
70 |
_ |
133 |
34.5 |
76 |
32 |
19 |
9 |
G ¼ |
(grade) 0009G |
|
1 |
K017 (grade) |
1.0 |
95 |
_ |
158 |
42 |
89 |
61 |
36 |
17 |
G ¾ |
(grade) 0017G |
|
1 |
K030 (grade) |
1.1 |
130 |
_ |
194 |
42 |
89 |
108 |
64 |
30 |
G ½ |
(grade) 0030G |
|
1 |
K058(grade)-B |
2.4 |
172 |
_ |
251 |
58 |
120 |
216 |
127 |
60 |
G ¾ |
(grade) 0058G |
|
1 |
K145(grade)-B |
2.9 |
272 |
_ |
351 |
58 |
120 |
288 |
170 |
80 |
G 1 |
(grade) 0080G |
|
1 |
K145(grade)-B |
2.9 |
272 |
_ |
351 |
58 |
120 |
432 |
254 |
120 |
G 1¼ |
(grade) 0125G |
|
1 |
K145(grade)-B |
2.9 |
272 |
_ |
351 |
58 |
120 |
522 |
307 |
145 |
G 1½ |
(grade) 0145G |
|
1 |
K220(grade)-B |
9.1 |
320 |
_ |
511 |
66.5 |
160 |
720 |
424 |
200 |
G 1½ |
(grade) 0205G |
|
1 |
K220(grade)-B |
9.1 |
320 |
_ |
511 |
66.5 |
160 |
792 |
466 |
220 |
G 2 |
(grade) 0220G |
|
1 |
K330(grade)-B |
12.9 |
625 |
_ |
816 |
66.5 |
160 |
1188 |
699 |
330 |
G 2 |
(grade) 0330G |
|
1 |
K430(grade)-B |
12.1 |
400 |
_ |
602 |
79 |
202 |
1440 |
848 |
400 |
G 2½ |
(grade) 0405G |
|
1 |
K430(grade)-B |
11.9 |
400 |
_ |
602 |
79 |
202 |
1548 |
911 |
430 |
G 3 |
(grade) 0430G |
|
1 |
K620(grade)-B |
20.9 |
625 |
_ |
844 |
79 |
202 |
2232 |
1314 |
620 |
G 3 |
(grade) 0620G |
|
3 |
K330(grade)-B |
44.5 |
570 |
_ |
1095 |
82 |
420 |
3600 |
2119 |
1000 |
G 4 |
(grade) 1000G |
|
1 |
K220 (grade) |
29 |
350 |
335 |
624 |
115 |
304 |
720 |
424 |
200 |
DN40 |
(grade) 0205F |
|
1 |
K330 (grade) |
37 |
650 |
335 |
934 |
120 |
304 |
1188 |
669 |
330 |
DN50 |
(grade) 0330F |
|
1 |
K620 (grade) |
64 |
650 |
335 |
1077 |
177 |
390 |
2232 |
1314 |
620 |
DN80 |
(grade) 0620F |
|
3 |
K330 (grade) |
95 |
650 |
335 |
1140 |
201 |
450 |
3600 |
2119 |
1000 |
DN100 |
(grade) 1000F |
|
4 |
K330 (grade) |
135 |
650 |
335 |
1220 |
230 |
500 |
4680 |
2755 |
1300 |
DN100 |
(grade) 1300F |
|
6 |
K330 (grade) |
177 |
650 |
335 |
1294 |
273 |
580 |
7020 |
4132 |
1950 |
DN150 |
(grade) 1950F |
|
10 |
K330 (grade) |
368 |
650 |
335 |
1519 |
361 |
750 |
11700 |
6886 |
3250 |
DN200 |
(grade) 3250F |
|
16 |
K330 (grade) |
515 |
800 |
335 |
1684 |
410 |
740 |
18720 |
11018 |
5200 |
DN250 |
(grade) 5200F |
|
24 |
K330 (grade) |
684 |
850 |
335 |
1777 |
485 |
1000 |
28080 |
16527 |
7800 |
DN300 |
(grade) 7800F |
|
1 |
K009AA & K006AC |
1.0 |
70 |
70 |
133 |
133 |
76 |
22 |
13 |
6 |
G ¼ |
AC-0006G |
|
1 |
K017AA &
K013AC
|
1.2 |
95 |
95 |
158 |
158 |
89 |
47 |
27 |
13 |
G ¾ |
AC-0013G |
|
1 |
K030AA &
K025AC
|
1.4 |
130 |
95 |
194 |
194 |
89 |
90 |
53 |
25 |
G ½ |
AC-0025G |
|
1 |
K058AA &
K040AC
|
3.2 |
172 |
125 |
251 |
251 |
120 |
144 |
84 |
40 |
G ¾ |
AC-0040G |
|
1 |
K145AA &
K065AC
|
3.7 |
272 |
125 |
351 |
251 |
120 |
234 |
136 |
65 |
G 1 |
AC-0065G |
|
1 |
K145AA &
K058AC
|
3.8 |
272 |
225 |
351 |
351 |
120 |
306 |
178 |
85 |
G 1¼ |
AC-0085G |